Veikals / Noliktava
|
27. novembris | Bez maksas |
|
|||
|
Ar kurjeru visā Latvijā
|
28. novembris | No 3,99 EUR |
|
|||
|
Piegādes punktos
|
28. novembris | No 1,99 EUR |
The universal meter 81784 with a manual range for each measurement enables the implementation of basic and advanced electrical measurements. Built -in additional measuring sockets facilitate measurement of, among others capacitors and transistors. An additional protection against mechanical damage is the so -called Holster - a rubber housing stretched onto the device housing. Basic measurements measurement of alternating voltage: A.C. 0-600V Fixed voltage measurement: D.C. 0-600V ACTION MEASUREMENT: A.C. 0-10A DC measurement: D.C. 0-10A resistance measurement: 0-200MΩ diode test: IF 1MA, UR 2.8V circumference continuity test: 0-30Ω Additional measurements Capacitor capacity measurements: 0-20μF Frequency measurement: 0-20kHz Temperature measurement: -40 to 400 ° C HFE transistors test: 0-1000, built-in measurement measuring socket of measurement. Example of determining accuracy for measuring AC alternating current voltage. Calculations for the measurement result: 235V Measurement accuracy of the 81784 meter for this range is: ± (1.2% + 5), 1V resolution 1V calculation of the measurement error Pattern: (measurement result x 1.2%) + 5 x Calculation resolution: (235 x 1, 2%) + 5 x 1 = 2.82 + 5 = 7.82V The result, taking into account the measuring error for indicating & nbsp 08V The result, taking into account the measuring error for indicating the measurement of alternating current: 8a = 8 ± 0.26a* Table with resolution and accuracy for a given measurement is in the user manual. *Meter 81784 does not have the TRUE RMS measurement function, which is why the above result is a real effective value of AC voltage only for the correct sinusoidal course. Additional information LCD display, & nbsp; Maximum score displayed: 1999 SUBSCRIPTION SUBJECT IN THE CIRCLE TREATMENT TEET FOR A resistance below 30Ω Automatic Diode test switching on the continuity test with a resistance & nbsp; circuit below 30Ω (inability to set the meter only on the diode test) In the set of measuring probes , the probe is a temperature measurement. Construction with overload protection ABS housing + so -called Holster, i.e. a rubber housing that protects the meter against mechanical damage, automatic switching off the meter low battery level. Power supply: 9V battery (6F22) Note in the case of measuring unknown values using a meter with a manual change of range using the knob, you need to make measurements in the highest range Up to the range giving the most accurate result - otherwise we risk damage to the device.Index: 81784
Barcode: 5906083817847
Unit of measure: PCE
Volume: 2.036
Weight: 0.625
Temperature: -40 ~ +400 ˚C
Capacity: 0-20 µF
Alternating voltage: 0-600 V a.c.
Bell ring: tak
Resistance: 0-200 MΩ
Alternating current: 0-10 A
Diode test: tak
Direct current: 0-10 A
Digit height: 25 mm
Auto power off: tak
Conduction test: tak
hFE transistor test: PNP|NPN
Application: elektryczne
Material: ABS
Continuity test: 0-30 Ω
Direct voltage: 0-600 V d.c.
Frequency: 20 kHz